AWK-5222 User’s Manual Other Console Configurations
3-39
The following parameters can be configured on the SNMP Agent page. A more detailed
explanation of each parameter is given below the following figure.
Enable
Setting Description Factory Default
Enable Enables SNMP Agent
Disable Disables SNMP Agent
Disable
Read community (for V1, V2c, V3 or V1, V2c)
Setting Description Factory Default
Read Community Use a community string match with a
maximum of 31 characters for authentication.
This means that the SNMP agent can access
all objects with read-only permissions using
this community string.
public
Write community (for V1, V2c, V3 or V1, V2c)
Setting Description Factory Default
Read /Write
Community
Use a community string match with a
maximum of 31 characters for authentication.
This means that the SNMP agent can accesses
all objects with read/write permissions using
this community string.
private
SNMP agent version
Setting Description Factory Default
V1, V2c, V3, or
V1, V2c, or V3 only
Select the SNMP protocol version used to
manage the switch.
V1, V2c