Installation
2-9
RS-422 Application
A typical RS-422 application for TCC-100 Series is depicted in the following
figure. In this scenario, two TCC-100 Series units are used to create a
point-to-point connection between a PC and Scales. The advantage of using two
TCC-100 Series units to convert from RS-232, to RS-422, and then back to
RS-232, is that the RS-422 cable connecting the two converters can be up to 1.2
km in length (this is quite an improvement compared to the 15-m distance
limitation imposed by the RS-232 interface).
MOXA
TCC-100 Series
MOXA
TCC-100 Series
RS-232
Rx(+/-) Tx(+/-)
RS-422 Point-to-Point
Communication
PC
Scales
PWR
RS-232 Tx
RS-232 Rx
Transio
RS-232 to RS-422/485
converter
RS-232
RS-422/485
Tx+(B)
Tx (A)
Rx+(B)(Data +)
Rx (A)(Data )
RTS+(B)
RTS (A)
CTS+(B)
CTS (A)
SGND
V+
V
DC9~30V
TCC-100
PWR
RS-232 Tx
RS-232 Rx
Transio
RS-232 to RS-422/485
converter
RS-232
RS-422/485
Tx+(B)
Tx (A)
Rx+(B)(Data +)
Rx (A)(Data )
RTS+(B)
RTS (A)
CTS+(B)
CTS (A)
SGND
V+
V
DC9~30V
TCC-100