- 8 -
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface such as a metal panel.
Wiring the Alarm Contact
The Alarm Contact is made up of the two middle contacts of the terminal block
on the IMC-101G’s top panel. Refer to the next section for detailed instructions
on how to connect the wires to the terminal block connector, and how to attach
the terminal block connector to the terminal block receptor.
In this section, we explain the meaning of the two contacts used to connect the
Alarm Contact.
FAULT
Top View
FAULT
Front View
FAULT: The two middle contacts of the
6-contact terminal block connector are used
to detect both power faults and port faults.
The two wires attached to the Fault contacts
form an open circuit when:
1. The IMC-101G has lost power from one
of the DC power inputs.
OR
2. One of the ports for which the
corresponding PORT ALARM DIP
Switch is set to ON is not properly
connected.
If neither of these two conditions occurs, the
Fault circuit will be closed.
Wiring the Redundant Power Inputs
The top two contacts and the bottom two contacts of the 6-contact terminal
block connector on the IMC-101G’s top panel are used for the IMC-101G’s
two DC inputs. Top and front views of one of the terminal block connectors are
shown here.
Top View
Front View
STEP 1: Insert the negative/positive DC
wires into the V-/V+ terminals, respectively.
STEP 2: To keep the DC wires from pulling
loose, use a small flat-blade screwdriver to
tighten the wire-clamp screws on the front of
the terminal block connector.
STEP 3: Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is located on IMC-101G’s top
panel.