Strany 1 - ’s Manual

Industio CP-114 Series User’s Manual 3 in 1 RS-232/422/485 Industrial Serial Board for PCI Bus Fifth Edition, June 2008 www.moxa.com/produ

Strany 2

33 3 Software Installation In this chapter, the software driver installation, configuration and driver update/removal procedures are described fo

Strany 3 - About This Manual

5. Select “Moxa Smartio/Industio Family multiport board” in the “Select OEM Option” dialog box, and click [OK] to enter the “Moxa Smartio/Industio

Strany 4 - Table of Contents

Software Installation 6. In the “Moxa Smartio/Industio Configuration Panel” dialog box, click [Add] to enter “Property” dialog box to add the Indus

Strany 5 - Introduction

z Rx FIFO Trigger Rx FIFO trigger levels, at 1, 4, 8 or 14 bytes, are available, and the default value is 14 bytes. z Tx FIFO Size Tx FIFO sizes

Strany 6 - Features

Software Installation Note ! Once the board and the driver are installed and the driver restarts successfully, you can start to develop applicatio

Strany 7 - Installation Guide

3-6 Industio CP-114 User's Manual Removing Driver To remove the driver for the Industio CP-114 board, 1. Open the [Control Panel], click on

Strany 8 - Hardware Installation

Software Installation The following flow chart illustrates the driver installation stages of the Industio CP-114 Series boards. Each stage is detaile

Strany 9 - Connecting the Fan-out Cable

Software Installation Industio CP-114 User's Manual 3-9 Windows 95 Windows 98 2. Click on the [Other Locations] button. 2. Select “Disp

Strany 10 - Software Installation

5. Type “A:\Windows.95” and click [OK] button. The system will start reading the files from the diskette. 6. Click [Next>] button.

Strany 11

Software Installation Industio CP-114 User's Manual 3-11 In the “CP-114 Series Installation” dialog box, select the desired port in the port

Strany 12

Industio CP-114 Series User’s Manual The product described in this manual is furnished under a license agreement and may be used only in accordance w

Strany 13

Board and Port Ready Stage Click [OK] for all the dialog boxes to finish the configuration and exit the “CP-114 Series Installation” dialog box. In

Strany 14 - Updating Driver

Software Installation Industio CP-114 User's Manual 3-13 Configuring Board and Port If you already have installed the driver and want to re-c

Strany 15 - Windows 95/98

Updating Driver This section explains how to update the driver. 1. In the [Control Panel], click on the [System] icon, select the [Device Manager]

Strany 16

Software Installation Industio CP-114 User's Manual 3-15 Removing Driver This section explains how to remove the Industio CP-114 Series board

Strany 17

DOS Moxa DOS API-232 is a software package that assists users to develop and/or debug programs for serial communications. This section will show you

Strany 18

Software Installation Industio CP-114 User's Manual 3-17 Driver Setup The following are steps for setting up the Industio CP-114 Series drive

Strany 19

Note ! Up to now you have completed the setup for Industio CP-114 Series board. You may skip this step and go dire

Strany 20 - Board and Port Ready Stage

Software Installation Industio CP-114 User's Manual 3-19 Port number: This is actually the port ID of each port. The application software wil

Strany 21

3-20 Industio CP-114 User's Manual Loading Driver Having completed the setup, you can load the driver, "BIN\DP-DRV.EXE", at the DOS

Strany 22

44 4 Serial Programming Tools Moxa supports some easy but powerful serial programming libraries and communication troubleshooting utilities under

Strany 23 - Removing Driver

About This Manual This manual is composed of six chapters and one appendix. This manual is written for installer, system administrator and software p

Strany 24 - Installing Driver

Utilities Following are short descriptions of each utility. For details, please see the on-line help on the diskette. Diagnostic (for Moxa boards o

Strany 25 - Driver Setup

Serial Programming Tools Monitor (for Moxa boards under Windows NT Only) A useful port status monitoring program that allows you to watch the select

Strany 26

Terminal Emulator The Terminal Emulator features multi-windows and supports terminal types of VT100 and ANSI. You can transfer data interactively, s

Strany 27

Serial Programming Tools DOS Installing API-232 API-232 Library is the professional serial programming tool for DOS. It is installed automatically

Strany 28 - Unloading Driver

Data Scope The Data Scope, BIN\SCOPE.EXE, is a suite of utility programs that can help users with system troubleshooting and serial communication de

Strany 29 - Serial Programming Tools

Serial Programming Tools RS-485 Programming If you intend to do RS-485 communication with Industio CP-114 Series, please follow the RS-485 programmi

Strany 30 - Utilities

4-8 Industio CP-114 User's Manual There are 2 solutions to control RS-485 2-wire transmission. Solution 1 The following model is common in RS-

Strany 31

5-1 55 5 Connection Cable and Cable Wiring In serial data communications, the term DTE is for Data Terminal Equipment, like PC COM1/2, serial print

Strany 32 - Terminal Emulator

Type 1: To connect the Industio CP-114 Series to a DTE device. PC COM2 port, Serial Printer,Terminal, or any DTE DeviceCP-114 5-2 Industio CP-114

Strany 33 - DOS API-232 Library

Connection Cable and Cable Wiring Type 2: To connect Industio CP-114 Series to a DCE device. Modemor any DCE DeviceCP-114 5-3 CP-114 DCE Device D

Strany 34 - Diagnose

Table of Contents Chapter 1 Introduction ...1-1 Overview..

Strany 35 - RS-485 Programming

RS-422 Cable Wiring The RS-422 standard uses a balanced voltage digital interface to allow 9600 bps communication over cables of up to 400 ft (1.2 k

Strany 36

Connection Cable and Cable Wiring RS-485 Cable Wiring The RS-485 standard is an enhanced version of the RS-422 balanced line standard. It allows mul

Strany 37 - RS-232 Cable Wiring

Impedance Matching and Termination Resistors For RS-422/485 serial communications, when an electrical signal travels through two different resistanc

Strany 38

Connection Cable and Cable Wiring DB37 Connector The following lists the pin assignments of the Industio CP-114 Series DB37 connector on the bracket

Strany 39

66 6 Troubleshooting Common Industio CP-114 Series problems and possible solutions are listed below. If you still have problems, contact your deal

Strany 40 - RS-422 Cable Wiring

6-2 Industio CP-114 User's Manual Log. This indicates that the Moxa board is found, but the IRQ is conflicting with another adapter. Please ma

Strany 41 - RS-485 Cable Wiring

AA A Technical Reference Specification  Bus interface: 32-bit PCI (Spec 2.1)  Number of ports: 2 (RS-232 or RS-422/485), 2 (RS-422/485) 

Strany 42 - 1 2 3 4

UART 16C550C The UART chip, 16C550C, is an intelligent asynchronous controller capable of supporting one full duplex channel that simultaneously tr

Strany 43

1-1 11 1 Introduction Overview Industio - Industrial Multiport Async Solutions for PCI The term Industio stands for smart multiport serial I/O

Strany 44 - Troubleshooting

Operating System Support Support for Windows NT, Windows 95/98 and DOS with user-friendly installation, configuration and performance. Moxa Serial

Strany 45

Introduction Check List Upon unpacking the Industio CP-114 Series, you should find items in the package:  Industio CP-114 Series 4 ports serial

Strany 46 - Technical Reference

2-1 22 2 Hardware Installation The installation of the Industio CP-114 Series consists of hardware and software installation. The respective sect

Strany 47 - UART 16C550C

z S2 Data Mode Selection Switch for Port 1/2/3/4: (Valid if JP5/6 is Left and S1 is ON) ON* Set the RS-485 port to Automatic Data Direction Contro